KB-212 Speaker Station Clear-Com Intercom Systems
Rev. B
10
© Clear-Com Intercom Systems 2000
Solution: Check connections and cable.
Scenario 2
The KB-212 has an internal failure.
Solution: Unit requires servicing.
• System operates incorrectly. The Talk Light does not come on
when Talk button is pressed or stays on until Talk button is
pressed and the Speaker is off when it should be on.
Scenario 1
Operating Mode switches are set incorrectly.
Solution: Refer to the option switch setting section of this manual.
•
Speaker does not operate. The Talk Light comes on when Talk
button is pressed
.
Scenario 1
Intercom Level knob turned all the way down.
Solution: Adjust control appropriately.
Scenario 2
Speaker plug or wiring has come loose.
Solution: Make sure speaker is connected internally.
Scenario 3
Plug P3 missing on circuit board.
Solution: Plug P3 must be installed in jack J3 if the EB-4W or EB-TW option is
not used.
• Hum or buzz in system
Scenario 1
Inductive pickup caused by close proximity of this speaker station or
connected stations to power lines or transformers.
Solution: Relocate the offending unit or wiring. If the cable run is exceptionally
long, consider adding and using the EB-4W 4-Wire Option Module. (Requires
an additional 4-wire interface at the opposite end of a “long run.”)
•
System feedback (Acoustical)
Scenario 1
Intercom Level control at this station or another station is set too high.
Solution: Adjust.
Comentarios a estos manuales